TECHNICAL DATA
Maximum working pressure: 1.4 MPa
Thread diameter of the air connection: 1/4 “
Maximum working temperature: 60 degrees Celsius
Tank material: Polycarbonate
Tank capacity: 8 cm3
INSTALLATION GUIDE
Place the device in a vertical position with the tank facing down.
Make sure that the connection is tight.
The filter should be placed in the pneumatic system as close as possible to the unit to which the filtered air is to be delivered.
Avoid exposure to direct sunlight, high temperatures and corrosive chemicals.
The water tank should be located below the water drain valve so that water can flow into it.
CONTROL
Dropping water
If there is no pressure, the water will automatically flow out.
If the device is under pressure, open the drain valve located on the bottom of the tank to allow water to fall.
If the water level exceeds the maximum allowable range, open the drain valve and let the water flow out. This will maintain the optimal humidification of the flowing air.
MAINTENANCE
Turn off the air supply, air collected under pressure in the pneumatic system let out into the atmosphere.
Turn the tank counterclockwise.
Clean the filter with clean, compressed air.
Clean the inside of the tank with a soft, dry cloth.
Do not use any solvents or other substances that could destroy polycarbonate.
Before screwing the reservoir retaining ring, make sure that the gasket is in place and not contaminated.
Technical data
Index number YT-2380
EAN 5906083923807
Brand Yato
Gross weight (kg) 0.1240
Master Carton MC 50
Inner Box IB 25
Pal 3000
Working pressure [MPa] 1.4
Max inlet pressure [bar] 14
Capacity [cm3] 8
The size of the quick connector [inch] 1/4 “
Thread diameter [in] 1/4 “